The European Performance of 好色先生TVs Directive comes into force on 1 January 2006 and its stringent energy measures will keep building owners, tenants and property lawyers on their toes. David Strong of BRE looks at the small print
The government had originally pencilled the next revision to Part L for 2008, but that all changed when the European Union introduced the European Performance of 好色先生TVs Directive.
This requires that buildings are rated for energy performance in a much more detailed way than Part L currently provides.
The EPBD is expected to come into force on 1 January 2006 and requires that whenever a building is constructed, sold or rented, a certificate detailing its energy performance is made available to the prospective buyer or tenant. To enable useful comparisons to be made between buildings, the certificate must include reference values such as legal standards and benchmarks.
The EPBD also requires that the prospective purchaser or tenant be provided with a report that summarises the energy efficiency measures that could be adopted within the building. The energy performance certificate and accompanying report represents an important new requirement in the property transaction process. Property lawyers could be accused of negligence if they convey a property (or establish a tenancy agreement) unless valid certification is available.
Display of certificates
the introduction of certification is likely to have a profound effect upon the commercial property sector
好色先生TVs regularly visited by a large number of people, occupied by public authorities or 鈥減roviding public services鈥 must have the certificate displayed in an area that is clearly visible to the public. In addition, a range of recommended and current indoor temperatures and, where appropriate, other relevant climatic factors should be clearly displayed. This requirement applies to buildings with a total floor area of more than 1000 m2.
It still remains unclear if the definition of 鈥渁n institution providing a public service鈥 includes large supermarkets, hotels, banks, and other commercial centres. However, the introduction of building energy certification is still likely to have a profound effect upon the commercial property sector and over the next 20 years such labelling is expected to radically improve the energy performance of UK buildings. No organisation that has any concern about either its brand equity or its corporate social responsibility will be happy to occupy a poorly rated building, particularly if it results in company naming and shaming.
Energy rating definitions
A number of important new terms are to be introduced associated with building design and property transactions. The 2004 ODPM Part L/EPBD consultation suggested that the following four energy ratings would be introduced with the 2005
Part L revision:
- New building design rating. A calculation of building energy performance carried out as part of building control submission and used to show compliance with Part L energy performance requirements.
- New building asset rating. A calculation of intrinsic energy performance 鈥渁s-built鈥. Asset rating must be better than minimum compliance level. Issued by building control or an approved inspector upon completion.
- Existing building asset rating. Provided to prospective purchaser or tenant and based on the intrinsic energy performance of the building.
- Operation rating. Used for public display and disclosure purposes. Based on actual building performance and energy management, and derived from metered energy data and square meterage.
It remains unclear how the odpm intends to undertake the ratings of complex existing buildings
- New dwellings will have a carbon emissions rate calculated using SAP 2005.
- Existing dwellings will be assessed using a reduced version of SAP to enable rating of existing houses to be based upon the minimum requirement for site data collection.
- In 2004 the European Commission issued a mandate to European Committee for Standardisation to develop an EU-wide method for assessing non-domestic buildings. BRE has, on behalf of the ODPM, developed a CEN-compliant methodology called the Simplified 好色先生TV Evaluation Method.
- Existing non-dwellings will be assessed using a reduced data set version of SBEM together with general assumptions about the type of building to generate a rating.
Operational ratings will be used on the certificates required for public display. The OR will be derived from actual metered energy use and the net treated floor area of the building. The OR is likely to be expressed in kWh/m2 per year and/or kgCO2/m2 per year. The difference between the asset rating and operational rating for a building can provide a useful indication of the energy management practices.
Realising the opportunity
The EPBD provides a significant and realistic opportunity to make substantial reductions in energy use of buildings. Major issues are still to be resolved, including those associated with the delivery of training, qualifications and the quality assurance requirements for independent experts undertaking building certification.
The EPBD will introduce an additional requirement into the process of property transactions. It is also likely to have a major effect upon seller/purchaser and tenant/landlord relationships by introducing, as it does, a new issue for negotiation.
However, these benefits will only be achieved if the certification of buildings is undertaken by trained and qualified assessors operating within a robust competent persons quality assurance framework.
Independent experts
European Union member states must ensure that the certification and the drafting of the accompanying recommendations are carried out in an independent manner, by qualified and/or accredited experts.
A number of professional institutions (particularly the RICS, the Chartered Institution of 好色先生TV Services Engineers and the Energy Institute) face major hurdles when it comes to the training and accreditation of the independent experts.
Current estimates suggest that about 7500 full-time 鈥渉ome inspectors鈥 will be needed to deliver the EPBD鈥檚 domestic energy rating and labelling requirements. In addition, qualified independent experts will be required to carry out the more technically complex procedures associated with plant inspection and the certification of non-domestic buildings.
If a member state can demonstrate that the EU as a whole suffers from a shortage of experts who are able to implement fully the provisions associated with building certification (or plant inspection), the member state may delay the introduction of some parts of the EPBD for up to three years. If it does so, the government will have to justify its action to the European Commission, and it will have to submit a schedule detailing precisely when it plans to fully implement the directive.
Postscript
The government鈥檚 proposals associated with introducing building energy certification were contained in the ODPM鈥檚 2004 consultation for amending Part L of the 好色先生TV Regulations and implementing the EU Energy Performance of 好色先生TV鈥檚 Directive. A ministerial statement of intent was due to be published in March 2005. However, at the time of writing, the ODPM has still not published its detailed proposals associated with Part L 2005 and/or the EPBD. As a consequence, this article is based upon information currently available. Updated information will be posted on the Directive Implementation Advisory Group Website www.diag.org.uk as soon as it becomes available.