Recreation building - Gross internal floor area 2100 m2 - 1970s design
LocationItemQuantityRateTotal £Priority £ - HighPriority £ - Medium
Entrance lobbyDisabled parking bays with dropped kerb:ÌýÌýÌýÌýÌý
Disabled parking bay27501,5001,500–
Dropped kerb 2200400400–
Sign on pole 2120240240–
Provide handrails and balustrade to side of ramp3 m200600600–
Provide kerb to side of ramp3 m50150150–
Paint bollards to improve contrast530150150–
Take up and relay broken paving100 m2303,0003,000–
Lay new footpath30 m2501,5001,500–
Paint high contrast bands around columns57 m10570570–
Provide new automatic doors48,00032,00032,000–
Provide paved access to sports grounds200 m2306,0006,000–
Paint ramp to indicate landing5 m1050–50
ReceptionLower section of reception desk11,5001,5001,500–
Provide locational signage1015150150–
Provide tactile signage generally650300300–
Remove existing portable noticeboard250100100–
Provide new permanently fixed noticeboard2200400400–
Fitness roomMove equipment to ensure circulation space1100100100–
Swimming poolLine marking to edge of pool 200 m102,0002,000–
Catering Lower kitchen base unit1500500500–
Replace carpet to improve contrast45 m2251,1301,130–
Replace cupboard doors with sliding doors1100100100–
Provide armless chairs to viewing area4200800800–
Provide lower kitchen unit for microwave25001,0001,000–
Changing areaProvide accessible facilities to public and staffÌýÌýÌýÌýÌý
male and female changing rooms:ÌýÌýÌýÌýÌý
Convert toilet for disabled42,50010,00010,000–
Shower cubicle with floor drainage and pull–down seat44,00016,00016,000–
Changing cubicle41,0004,0004,000–
SignageImprove signage throughout whole building5015750750–
Internal doorsProvide new single doorsets including enlargeÌýÌýÌýÌýÌý
existing structural opening61,3508,1008,100–
Replace existing pairs of double doorsets withÌýÌýÌýÌýÌý
new 1.5 doorsets86004,800–4,800
Enlarge existing single door opening and ÌýÌýÌýÌýÌý
provide new door11,1001,1001,100–
StaircasesProvide new internal stairs 122,50022,500–22,500
Fire exitsProvide new ramps to fire exits65003,000–3,000
LiftProvide new two-storey lift170,00070,000–70,000
Subtotal for recommendations in access reportÌýÌýÌý94,140100,350
Add preliminaries @ 20%ÌýÌýÌý18,83020,070
Subtotal ÌýÌýÌý112,970120,420
Add contingencies @ 15%ÌýÌýÌý16,95018,060
SubtotalÌýÌýÌý129,920138,480
Above excludes professional fees and VATÌýÌýÌýÌýÌý
Flooring costs: Finishes, upper floors and lower-floor structures
Indicative inclusive rates for various types of floor finishes and structures, representing average contract rates in February 2004. Costs exclude screeds. Ranges reflect specification, quantity and regional price differences.
FinishesÌýÌý
DescriptionunitCost range £
Access floorsÌýÌý
150 mm high raised access flooringm235–45
ScreedsÌýÌý
50 mm thick cement sand screedm212–18
Ceramic tilingÌýÌý
Vitrified ceramic floor tiles with coved skirtingm235–55
Timber flooringÌýÌý
22 mm thick Hardwood flooring, tongued and grooved, underlaym265–85
Rubber flooringÌýÌý
4mm studded rubber flooring including edge detailsm235–45
Plastic tiling/sheetingÌýÌý
2.5 mm slip resistant vinyl flooring including edge detailsm225–35
2 mm thick anti–static vinyl flooring including edge detailsm230–40
LinoÌýÌý
2.5 mm thick linoleum flooring including edge detailsm222–30
Carpet tiling/sheetingÌýÌý
Carpet tilesm218–25
Carpet, manmade including underlaym220–30
Carpet, 70% wool including underlaym230–40
SkirtingsÌýÌý
Softwood skirtingm5–8
Hardwood skirtingm10–12
Entrance mattingÌýÌý
Entrance matting with aluminium framem2250–450
Composition block flooring ÌýÌý
Sprung composition block flooring m2 65–75
Upper floor structures ÌýÌý
Reinforced concrete slab on permanent metal decking m2 35–45
Prestressed precast concrete plank flooring m2 35–45
Precast concrete beam with block infills m2 35–45
Precast concrete composite floor with structural screed m2 55–70
Softwood suspended floor, joists, insulation and boarding m2 35–50
Lower floor structuresÌýÌý
Thermal insulation below ground floor slabs ÌýÌý
Rigid foam insulation board, 50 mm thick m2 7–9
Acoustic insulation to timber upper floors ÌýÌý
Glass wool insulation laid across battens, 25 mm thick m2 6–8